NEW QUESTION # 244
What are the common cabinet specifications in the FusionModule2000 configurator? (Multiple choice)
- A. 600*1200*2200
- B. 800*1200*2000
- C. 600*1200*2000
- D. 800*1200*2200
Answer: A,B,C,D
NEW QUESTION # 245
The () air supply method is suitable for data centers with high power density of a single cabinet.
- A. Under the floor
- B. Upper air duct
- C. Upper air supply
- D. Row level
Answer: D
NEW QUESTION # 246
Before the battery is installed, the open circuit voltage of a single battery is required: 12V battery ≥ 12 60V or 2V TV ≥ 2 10V, when it is found to be unqualified, the battery needs to be supplemented.
- A. True
- B. False
Answer: A
NEW QUESTION # 247
When the battery is discharged, the discharge voltage of a faulty battery drops rapidly, and the backup time of the entire battery rented in the morning is not enough, so it should be dealt with ().
- A. No processing required
- B. Force equal charge, replace the faulty battery
- C. to discharge
- D. Scrap the entire battery pack
Answer: B
NEW QUESTION # 248
Which type of circuit breaker used in the sub-circuit of the PDU8000 precision power distribution cabinet?
- A. Molded Case Circuit Breakers
- B. Miniature circuit breakers
- C. Frame circuit breaker
- D. Disconnect switch
Answer: B
NEW QUESTION # 249
The FusionModule800 does not need to be charged with refrigerant on site within 30m of the connecting pipe.
- A. True
- B. False
Answer: A
NEW QUESTION # 250
What are the main reasons for the energy saving effect of closed cold/hot aisle? (Multiple choice)
- A. Isolate the cold air, avoid the confusion of the hot air, and improve the utilization rate of the air
- B. By increasing the supply air temperature, the amount of humidification is reduced, thereby reducing the power consumption of humidification
- C. It can increase the supply air temperature of the air conditioner, thereby reducing the energy consumption of the air conditioner
- D. The closed hot aisle can increase the return air temperature and improve the cooling efficiency
Answer: A,B,C,D
NEW QUESTION # 251
In the process of disconnecting the battery pack switch, if there are multiple sets of batteries, first disconnect the main switch between the battery pack and the UPS, and then disconnect the switch of each battery pack.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION # 252
Which of the following statements about UPS5000-E are correct? (Multiple choice)
- A. The output power factor can reach 1
- B. Modules are easy to expand
- C. High Power Density Design
- D. Pre-maintenance is not supported
Answer: A,B,C
NEW QUESTION # 253
NETCOL5000-C needs to manually adjust the water valve to the minimum when filling and exhausting water.
- A. FALSE
- B. TRUE
Answer: A
NEW QUESTION # 254
When NETCOL5000-A is charged with nitrogen to maintain pressure, the required nitrogen cylinder must be equipped with a pressure reducing valve.
- A. True
- B. False
Answer: A
NEW QUESTION # 255
The form of humidifier adopted by the row-level chilled water intelligent temperature control product NetCol5000-C032H is ( ). (Fill in the blank)
- A. Wet film
Answer: A
NEW QUESTION # 256
Two UPS2000-Gs with different software versions can be connected in parallel.
- A. True
- B. False
Answer: B
NEW QUESTION # 257
There is no limit to the total length of the refrigerant piping of the direct expansion air-cooled air conditioner.
- A. True
- B. False
Answer: B
NEW QUESTION # 258
Which of the typical configurations of FusionModule800 are standard?
- A. Smoke sensor, temperature and humidity, pad, SMS alarm, mobile APP, automatic pop-up door
- B. Temperature and humidity, door sensor, pad, water flood, video, mobile APP
- C. Smoke sensor, door sensor, pad, water immersion, simple wiring trough, video
Answer: A
NEW QUESTION # 259
The temperature control laboratory has passed the GMPI certification.
- A. True
- B. False
Answer: A
NEW QUESTION # 260
Suppose a certain battery specification stipulates that the discharge power is [email protected]@15min. If the system demand is 1400W, the number of battery packs to be selected is ().
- A. 4 groups
- B. 3 groups
- C. 5 groups
Answer: B
NEW QUESTION # 261
Two UPS5000-E (50kVA power modules) 150kVA, rack 1+1 redundancy, in the total input power cabinet, the required total input switch is ()
- A. 500A
- B. 320A
- C. 250A
- D. 630A
Answer: B
NEW QUESTION # 262
By setting the mailbox parameters, the NETECO system will send emails to notify users according to the set rules.
- A. True
- B. False
Answer: A
NEW QUESTION # 263
......